Malicious infrastructure

How to report a malware site or C2 server

Build a verifiable malware and C2 evidence package, find the right abuse contact and go upstream when the host does not answer.

Updated

A malware report becomes useful when a network engineer can reproduce the finding without guessing. The strongest package connects the hostname, the IPv4 address, the port, the protocol, the observation time and the behavior that makes the endpoint harmful. That package can go to a hosting provider, its network operator, an intelligence feed and the registrations behind the infrastructure.

What to collect: a report you can verify

Start with the evidence your sensors already produced. A URL and a screenshot are useful, but the route is the part a network operator can act on. Record the DNS response, the final destination and the first and latest observation times. Keep time in UTC and preserve the request and response metadata in a form another analyst can inspect.

Evidence for a malware or C2 report
LayerCollectWhy it matters
NameURL, hostname, redirect chain, DNS A, AAAA, CNAME and NS recordsShows how a victim reaches the service and which registrations control it.
AddressIPv4 address, IPv6 address, ASN, announced prefix and observation timeGives the hosting provider and network operator a route they can verify.
ServicePort, protocol, HTTP method, user agent, response headers, status and TLS certificate fingerprintSeparates the abusive service from other customers and shows what the endpoint does.
PayloadFile name, type, size, SHA-256 hash and malware family when knownLets a feed, host or analyst identify the sample without requiring a live download.
BehaviorBeacon interval, command format, new domains, processes and affected hosts observed in telemetryShows why the endpoint is command-and-control rather than a harmless service.

The reserved IPv4 addresses 192.0.2.0/24,198.51.100.0/24 and 203.0.113.0/24 are useful in a report template or training case. Never replace them with a real address until the finding is verified by telemetry. A copied configuration value can send an operator to the wrong network.

Collect the route, not just the URL

Resolve the hostname and preserve every answer. CDNs, fast-flux DNS and compromised websites can change the address under the same name. Query the address through RDAP, compare the announced prefix and capture the BGP route at the same time as the HTTP observation. If a C2 domain uses several A records, list each one and link it to the observation that used it.

A short command record can help another analyst reproduce the lookup. These examples use documentation names and addresses:

dig c2.yourbrand-example.net A
dig c2.yourbrand-example.net AAAA
curl -sS -D headers.txt https://c2.yourbrand-example.net/health
openssl s_client -connect c2.yourbrand-example.net:443 -servername c2.yourbrand-example.net

Use the least invasive method that proves the endpoint. If you already have endpoint telemetry, preserve the request URL, process, parent process and command line metadata instead of sending new traffic. If you must probe, use a controlled analysis system and record the date, source address and exact request. The report is stronger when the host can see what was observed and how.

The ICANN RDAP overview explains how registration data is exposed. Regional registry records identify the network object and abuse contact, while a public routing view shows the upstream relationships. A local traceroute can show a path from one vantage point, but it does not prove the full route. Use it as context, not as a substitute for the prefix and network record.

Host and network abuse contacts

The hosting provider controls the customer account. The network operator controls the route that serves the address. Both can act, but they need different parts of the evidence. Send the host the URL, page behavior, account identifier if you have one, and the exact request. Send the network operator the IPv4 address, announced prefix, port, protocol and the reason the endpoint is abusive.

  1. Find the hosting provider from the address, DNS history and page response.
  2. Find the abuse contact in the RDAP network object or the provider’s published abuse route.
  3. Name the affected URL and address in the subject line.
  4. State the first and latest observation times and the safe evidence you have.
  5. Ask for the account or endpoint to be suspended; ask the network to block or null-route the address if the host does not act.
  6. Request a case reference and preserve the reply with the original evidence.

Do not send live credentials, customer data or a full packet capture without a reason. Safe hashes, de-identified telemetry and a small set of relevant network records are enough to identify the service. If a host asks for the sample, provide it through a controlled channel and keep the hash in the report.

Share with intel feeds

A confirmed C2 endpoint can help other defenders after the host has received the case. Share the infrastructure and indicators in a format the receiving community can ingest: a MISP event, a STIX bundle or the public submission form for a malware URL feed. TheMISP project publishes an open threat-sharing platform, andURLhaus accepts malicious URL reports. CISA’sreporting page is a public route for incidents that need government coordination.

Include the context that prevents a feed entry from becoming a false positive: first seen, last seen, hosting network, protocol, certificate fingerprint, related file hash and the behavior observed on a host. Mark confidence and provenance. A feed can distribute an address faster than a single abuse ticket, but the host still controls the account and the network still controls the route.

If the infrastructure is used for spam, scanning or malware delivery across many addresses, preserve the grouping. A feed entry for one hostname does not describe the whole range. A report grouped by announced prefix and shared behavior gives responders a pattern they can compare with their own telemetry.

The host does not answer: go upstream

When a host ignores a verified C2 report, send the case to the network that announces the address. State the earlier report and the observation that the service is still online. Ask for the next control to act: block the endpoint, suspend the hosting route or null-route the abusive address. Keep the request specific because the network may not control the customer account.

The registrar is another layer when the C2 is reached through a domain that changes address or uses new subdomains to avoid blocks. The domain registration and DNS records can reveal a pattern that a single IPv4-address report misses. Platform abuse routes matter when the payload is delivered through an app, cloud account, file host or social page. Each operator sees a different part of the operation.

A formal letter and direct call can bring the evidence to a named abuse owner. The letter should repeat the technical facts, attach the same safe evidence and request action on the current live resource. The call should establish who owns the case and what route remains if the first team cannot act.

Abusive ranges and shared patterns

Convert one confirmed endpoint into a range-level case only when the evidence supports the link. Look for the same beacon, command format, certificate, redirect chain, hosting reseller, registration pattern or payload family. Then group the findings by announced prefix and show which addresses remain active.

A useful range report has one row per observation: hostname, IPv4 address, port, first seen, latest seen, response and evidence hash. A second view groups the rows by prefix. The network operator can then see why the addresses belong together and choose a response that covers the operation rather than a single hostname.

Remove stale addresses before submission. A range that once hosted a phishing page may now be reassigned to a legitimate customer. The current route, current response and current observation are what make the report actionable. Keep the historical record, but separate it from the live indicators.

How LARUS acts

LARUS brings the threat to the operator that can switch it off. We start with the host and the network that announce the malicious endpoint, then follow the registrar, platform and upstream route when the first layer does not act. The largest network on Earth means we can reach the network operators behind infrastructure that an ordinary abuse ticket may never leave.

Every plan includes automated takedown notices across the control chain. If a host ignores the report, a human escalation puts our in-house legal team on the case with a formal letter and direct calls. The case is counted only when the threat is down. For one live case without a subscription, the price is $299; for continuous protection, compare plans and prices.

For the C2 route, explore malware and C2 takedown orstart protection with the URL, IPv4 addresses, port, observation times and safe hashes you have already collected.

Questions

What people ask next.

Should I send the malware sample with the first report?

Start with the hash, behavior and safe metadata. Send the sample only through a controlled channel when the receiving team asks for it, and keep the original hash in the case record.

What does a network operator need that a host does not?

A network operator needs the IPv4 address, announced prefix, port, protocol and the observation that shows why the endpoint is abusive. The host also needs the customer service or account evidence behind the page.

When should I share the C2 in an intelligence feed?

Share it after you have confirmed the finding and preserved provenance. Include first seen, last seen, route, certificate fingerprint, related hashes and behavior so other defenders can verify it.

Take it down with us

You have the evidence. We have the route to the operator.

LARUS finds who controls the threat, sends the notices and stays on the case until it is down. Lawyers take over every human escalation.

Have a threat that needs action?

Tell us what is happening. The largest network on Earth goes to work for your brand.